mainPomocník pre správcu štartuWelcome to openSUSE Leap 15.0 Use this menu to select the desired function. If you have problems navigating in this help system, press F1 to enter the helpPopis of the help system. The main functions in this menu are: harddiskSpustiť systém z pevného disku: This selection will not do anything to the system. It only starts a previously installed operating system. linuxInštalácia: This installation mode works on most machines. If you experience a system freeze during boot or problems with detection of your hardware components, such as disk controllers or network cards, try one of the following installation options. noacpiInštalácia - bez ACPI: Many of the currently-sold computers have incomplete or faulty ACPI implementations. This selection disables ACPI support in the kernel, but still enables many performance features, like DMA for IDE hard disks. nolapicInštalácia - bez lokálneho APIC: If the normal installation fails, this might be due to the system hardware not supporting local APIC. If this seems to be the case, use this option to install without local APIC support. failsafeInštalácia -- Záchranný režim: If you were not successful with Inštalácia, this selection might solve the issue. rescueZáchranný systém: This boot image starts a small Linux system in RAM. This is useful if the system does not start properly. After booting this system, log in as root. firmwareTest firmvéru: Runs a BIOS test tool that validates ACPI and other parts of your BIOS. memtestTest pamäte: Memory testing is useful for more than checking installation of new memory modules. It is a stress test for a big part of your computer system and may indicate hardware problems. optMožnosti štartu: The boot options may change the behavior of your system completely. They are settings for the kernel. helpF1 Help: This is context sensitive. It will show different screens depending on the active element of the boot screen. There is also a description of this help system available. keytableF2: Set language and keyboard mapping used by the boot loader. videomodeF3 Video Mode: Here, choose between different screen resolutions while installing. If you encounter problems with the graphical installation, the Textový režim may be a work-around for you. install_srcF4 Installation Source: Choose the installation source. driverupdateF6 Driver Update: For very new machines, a driver update may be needed to install the system.bitsVýber typu sofvéruYou have the choice to install the 32-bit or 64-bit version of openSUSE Leap 15.0. Return to mainPomocník pre správcu štartudriverupdateAktualizácia ovládačovIf you need a driver update floppy or CD-ROM, press F6. The boot loader asks you to insert the driver update medium after loading the Linux kernel. A driver update is typically a floppy with new versions of hardware drivers or bug fixes needed during installation. Return to mainPomocník pre správcu štartufailsafeInštalácia -- Záchranný režimSelect Inštalácia -- Záchranný režim if you encounter hangs while installing or irreproducible errors. This option disables DMA for IDE drives and all power management features. See also the kernel options for o_apmapm, o_acpiacpi and o_ideide. Return to mainPomocník pre správcu štartufirmwareTest firmvéruStarts a BIOS checker that validates the ACPI tables and many other parts of your BIOS. Test results can be stored on usb disk or saved via network. Return to mainPomocník pre správcu štartuharddiskSpustiť systém z pevného diskuSelect Štartovať nainštalovaný systém to start the system installed on your local hard disk. This system must be installed properly, because only the MBR (Master Boot Record) on the first hard disk is started. The device ID of the first hard disk is provided by the BIOS of the computer. Use this if you forgot to remove the CD or DVD from your drive and want to start the computer from the hard disk. Return to mainPomocník pre správcu štartuhelpAko používať tohto pomocníkaThe boot loader online help is context sensitive. It gives information about the selected menu item or, if you are editing boot options, it tries to look up information about the option in which the cursor is positioned. Navigation Keys   • Šipka hore: highlight previous link • Šipka dolu: highlight next link • Šipka vľavo, Backspace: return to previous topic • Šipka vpravo, Enter, Medzerník: follow link • kláves Page Up: scroll up one page • kláves Page Down: scroll down one page • Domov: go to page start • kláves End: go to page end • Esc: leave help Return to mainPomocník pre správcu štartuinstall_srcInštalačný zdrojPress F4 to choose an installation source. This is the same as using the o_installinštalovať boot option. Return to mainPomocník pre správcu štartukeytableVoľba jazyka a klávesnicePress F2 to change language and keyboard layout the boot loader uses. Return to mainPomocník pre správcu štartulinuxInštaláciaSelect Inštalácia to start the default installation. The optMožnosti štartu entered are used in the start-up. This item activates many features of commonly available hardware. Return to mainPomocník pre správcu štartumemtestTest pamäteThe included Test pamäte provides good possibilities to stress test the hardware of a system. Its main purpose is to detect broken RAM, but it also stresses many other parts of the system. There is no guarantee that the memory is good if no errors are found, although most of memory defects will be found. Return to mainPomocník pre správcu štartunoacpiInštalácia - bez ACPICurrent hardware usually requires ACPI (Advanced Configuration and Power Interface) to control the interrupt handling. ACPI completely replaces the old APM system. Select Inštalácia - bez ACPI if you encounter problems during boot of the kernel. Known problems with machines that have problems with ACPI are:   • kernel freezes when booting • PCI Cards are not detected or initialized properly You may also try the firmwareTest firmvéru boot option and look at the test results of the ACPI validation. Return to mainPomocník pre správcu štartunolapicInštalácia - bez lokálneho APICNormally there are no problems with the APIC (Advanced Programmable Interrupt Controller). But if you seem to have some, try this option to boot without local APIC support. Please don't confuse this with noacpiACPI (Advanced Configuration and Power Interface). Return to mainPomocník pre správcu štartuoptMožnosti štartuThere are two types of boot options available. First, there are options that affect the installer. Second, there are kernel options. Some of the more common options are: a) installer options   • o_installinštalovať -- select an installation source • networkvoľby siete -- the network options • o_vncVoľby vnc -- options for installation via VNC b) kernel options   • o_splashúvodná obrazovka -- influence the behavior of the splash screen • o_apmapm -- toggle power management • o_acpiacpi -- advanced configuration and power interface • o_ideide -- control the IDE subsystem Return to mainPomocník pre správcu štartuo_hostipo_netmasko_gatewaynetworkInštalačné možnosti: Sieťové voľbyIt is possible to configure the network interface right now. The hardware will be detected later by YaST2. The minimum set of options to configure your network card consists of host IP and netmask. For example:   • hostip=192.168.0.10 netmask=255.255.255.0 or in a shorter form:   • hostip=192.168.0.10/24 If you specified a o_installinštalácia po sieti and do not specify both of these options, the installer tries to configure the network interface with dhcp. If you need a default gateway, specify this with the option brána. For example:   • gateway=192.168.0.8 Return to optMožnosti štartuo_acpiVoľba jadra: acpiACPI (Advanced Configuration and Power Interface) is a standard that defines power and configuration management interfaces between an operating system and the BIOS. By default, acpi is switched on when a BIOS is detected that is newer than from year 2000. There are several commonly used parameters to control the behavior of ACPI:   • pci=noacpi -- do not use ACPI to route PCI interrupts • acpi=oldboot -- only the parts of ACPI that are relevant for booting remain activated • acpi=off -- switch off ACPI completely • acpi=force -- switch on ACPI even if your BIOS is dated before 2000 Especially on new computers, it replaces the old o_apmapm system. Return to optMožnosti štartuo_apmVoľba jadra: apmAPM is one of the two power management strategies used on current computers. It is mainly used with laptops for functions like suspend to disk, but it may also be responsible for switching off the computer after power down. APM relies on a correct working BIOS. If the BIOS is broken, APM may have only limited use or even prevent the computer from working. Therefore, it may be switched off with the parameter   • apm=off -- switch off APM completely Some very new computers may take more advantage from the newer o_acpiACPI. Return to optMožnosti štartuo_ideVoľba jadra: ideIDE is, unlike SCSI, commonly used in most desktop workstations. To circumvent some hardware problems that occur with IDE systems, use the kernel parameter:   • ide=nodma -- switch off DMA for IDE drives Return to optMožnosti štartuo_installVoľba inštalácie: instaláciaBy default, the local CD-ROMs are searched for the installation source. For a network install, select the inštalovať option. Possible installation protocols are   • FTP • NFS • HTTP The syntax to use is just like standard URLs. For example, if your server is found at 192.168.0.1 and you want to do an NFS-based install from the directory /install on this server, specify the source as follows:   • install=nfs://192.168.0.1/install The network card will either be configured with dhcp or you must specify the parameters yourself as described in the networkvoľby siete. Return to optMožnosti štartuo_splashVoľby jadra: úvodná obrazovkaThe splash screen is the picture shown during system start-up.   • splash=0 -- The splash screen is switched off. This may be useful with very old monitors or if some error occurs. • splash=verbose -- Activates splash, kernel and boot messages are still shown. • splash=silent -- Activates splash, but no messages. Instead a progress bar is drawn. Return to optMožnosti štartuo_vncpasswordo_vncVoľba inštalácie: vncTo enable the VNC installation, specify the parameters vnc and vncpassword:   • vnc=1 vncpassword=mojeheslo The VNC server will be started and you may control YaST2 over any VNC client from a remote system. Return to optMožnosti štarturescueZáchranný systémThe Záchranný systém is a small RAM disk base system. From there, it is possible to make all kinds of changes to an installed system. Because only low-level tools are available in this system, it is intended for experts. Return to mainPomocník pre správcu štartuvideomodeVoľba zobrazovacieho režimuPress F3 to get the list of video modes your graphics card supports. The highest mode your monitor can display is preselected. It is possible that your monitor cannot be detected automatically. In that case, select your preferred mode manually. If your system has problems with the graphics card during the installation, the Textový režim may be a usable work-around. Return to mainPomocník pre správcu štartu